RB1410
Liebherr RB1410 BioFresh Refrigerator – Built-In Column Repair

Most common issues on this model
- BioFresh drawer slides that drag or have dropped out of line
- Door gasket worn on the hinge side
- Evaporator fan that squeals, stops or clicks
- Clogged defrost drain that leaves water at the bottom of the cabinet
- LED lighting that has gone dark in the refrigerator or BioFresh area
The RB1410 shows up in kitchens as one half of a 48-inch side-by-side, paired either with a freezer column in the SBS 243 or with a wine and freezer column in the SBS 246. By itself it holds 12.8 cubic feet, split between the main refrigerator and BioFresh, and it was listed in both the 2009 and 2013 design guides.
Our approach on this model is to test the drawers first, since BioFresh runs colder than the shelves and its full-extension slides carry the heaviest loads. After the drawers we check the fan, the evaporator for frost, and the drain, then the gasket along the hinge edge.
Since the unit is a pair partner, we also look at the seam between the two cabinets, where a gap lets warm air enter. We quote in writing before any work, and every repair comes with a 30-day workmanship warranty.
Key features
- 24-inch built-in BioFresh refrigerator, stainless
- 12.8 cu ft total: refrigerator 8.7 cu ft (246 L), BioFresh 4.1 cu ft (117 L); 320 kWh/yr
- Right hinge, reversible; SN-T; 115V/60Hz/350W
- Automatic defrosting, LED lighting and full-extension BioFresh drawers; pairs with F/FI 1051 (SBS 243) or WF/WFI 1061 (SBS 246)
Error codes this model can show
Do I have to service the freezer column along with the RB1410?
No. Each column has its own cooling circuit, so the RB1410 can be repaired alone. We do look at the joint between cabinets, because a misaligned seam shows up as sweating on either unit.
Why do my herbs freeze in the BioFresh drawer?
The BioFresh drawer runs near 32°F, so a sensor that reads high or a fan that overcools can freeze leaf produce. We check the sensor, damper and humidity setting, then adjust or replace what has drifted.
What kind of water leak shows up on this unit?
Meltwater from the defrost cycle goes to a drain. When food debris clogs it, the water backs up into the cabinet floor. We clear the line and check the heater so the water drains away again.
Book repair for your RB1410
Book online in about a minute, or give us a call. Same-day appointments are available inside the Loop on most days, and next-day service across the rest of Houston.